Burn
Units are run at high ambient temperature (50ْ C) while being
power cycled for a period of from 8 to 96 hours. All outputs of the
units are monitored during this test and the time to failure is re corded
in the quality database for each unit by serial number. Other levels
of burn include Environmental Stress Screening (ESS) and Highly
Accelerated Stress Screening (HASS). ESS is a thermal stress, of ~1
degree C/minute while the unit if operational and being monitored.
HASS is a combination of thermal and vibration, of ~ 1 degree C/Second
and a vibration of 50G’s max while the unit if operational and being
monitored. (OVS-3 HALT/HASS Chamber,
pictured right)
Final test
Final test is
designed to detect any changes to units during burnin. It is a
complete Hi Potential safety test and full load functional test. These
test are done by program controlled automated test equipment which
records all test results in the quality database by serial number for
each unit tested.
A quality
inspection of each unit is performed after test to assure all test and
quality checks have been performed
and
that unit
appearance and labeling is correct. (Burn-in
rooms, pictured left) |