Manufacturing
→
Test
|
Our comprehensive test and
verification ensures quality products. Documented records of
all tests are maintained and the personnel who conduct these tests are
qualified and trained specifically for this test activity.
|
|
Test
▪ Design Verification
Testing (DVT)
▪ HALT
▪ High volume Burn-in/HASS (Production Test)
▪ EMC Testing
▪ Visual test
▪ Configuration verification
▪ PCB continuity/resistance cable tests and crimp verification
▪ Software control burin-in bays
▪
Test Engineering
▪ Automated, Scripted, Custom, Safety (leakage and Hipot)
▪ Safety approvals
▪ Thermal test
▪ System stress
▪ Shock and vibe
▪ Complex tech analysis
|
|
Design Verification Testing
Tracewell Electronics performs complete design verification
testing (DVT). Using Tracewell’s extensive testing and laboratory
facilities, Tracewell’s professional engineering staff can design,
troubleshoot and qualify your product at any stage of its life cycle. |
|
HALT
Whether done independently, or as part of the DVT testing,
Tracewell can perform Highly Accelerated Life Testing (HALT). During
this test, the product is driven beyond its normal operating conditions
of temperature and vibration and brought to the point of failure. HALT
testing is a requirement for all designs with the goal of forcing out
latent failures early in the product life cycle, prior to the start of
production. Of particular interest would be those which are due to
inadequate derating or substandard design. Failures are analyzed
and, if necessary and/or economically feasible, will be eliminated from
the design. The test/cycle continues until it is no longer necessary or
reasonable to proceed. This process enhances the durability and overall
reliability of the product. As part of normal production, the HALT
profile can be reduced to a production level test, Highly Accelerated
Stress Screening (HASS). HASS can be performed continually or on an
audit basis to monitor process issues.
|
|
First test
First test is a combination of Hi Potential safety test and full
load functional test. These test are done by program controlled
automated test equipment which records all test results in the quality
data base by serial number for each unit tested.
Burn
Units are run at high ambient temperature (50 C) while being power
cycled for a period of from 8 to 96 hours. All outputs of the units are
monitored during this test and the time to failure is recorded in the
quality database for each unit by serial number. Other levels of burn
include Environmental Stress Screening (ESS) and Highly Accelerated
Stress Screening (HASS). ESS is a thermal stress, of ~1 degree C/minute
while the unit if operational and being monitored. HASS is a
combination of thermal and vibration, of ~ 1 degree C/Second and a
vibration of 50G’s max while the unit if operational and being
monitored.
Final test
Final test is designed to detect any changes to units during burnin.
It is a complete Hi Potential safety test and full load functional test.
These test are done by program controlled automated test equipment which
records all test results in the quality database by serial number for
each unit tested. A quality inspection of each unit is performed
after test to assure all test and quality checks have been
performed and that unit appearance and labeling is correct. |
Thermal
Mechanical design,
modeling and analysis are accomplished using Cadkey, Solidworks, Autocad,
Flomerics FLOTHERM and Mathcad. Mechanical models, from the individual
component to the overall system are created in Cadkey and Solidworks.
Flomerics FLOTHERM and Mathcad are used for thermal and structural
analysis. Prototypes are also fabricated in Tracewell’s sheetmetal
facility for design verification and testing |
|
EMC
Tracewell has established an on-site pre-compliance EMC facility for the
testing of products under development and for the random audit of
production units. The state of the art facility includes a screen room
and a compact 3 meter anechoic chamber. A dedicated staff member
assures consistent procedural test methods with data recording and
backup. Testing is under software control for conducted emissions,
radiated emission and surge testing. A manual test system is employed
for ESD compliance testing. Our engineering staff enjoys a complete
complement of troubleshooting tools for use investigating emissions.
These tools include a variety of probes for use with a selection of
network and spectrum analyzers.
|
Reliability
Tracewell Electronics’ engineering staff routinely performs design MTBF
calculations to either Mil handbook or Bellcore. Where appropriate,
commercial data is used in the calculation. In agreement with
customers, samples of production units are subjected to ongoing
reliability tests (ORT) to detect any latent defects in an accelerated
temperature burn-in. Where selected products have been traceable field
MTBF numbers have been achieved well in excess of 1,000,000 hours. |
|
Data Collection
Several reporting mechanisms have been developed throughout our
organization to collect, store, evaluate, and disseminate data
information from the design phase through end-of-life manufacturing.
Process databases collect data from throughout the manufacturing process
including board assembly test, unit first test, burn-in or ESS, unit
final test final inspection, and pack. Repair loops database all
repairs at board assembly level and unit level. Our return goods area
databases all repairs on returned product. These databases provide
the ability to query for selected data criteria, as well as establish
Pareto analysis and Cpk studies for process improvement.
A conscious effort is made to improve data collection. Current efforts
include upgrading our returned goods database, expanding data collection
to other inspection points, and incoming component transformer
parameters.
|
|
|